SUN STORAGETEK 2540 控制器firmware更新

You are here:
< All Topics

HELLO GUYS

又到了大家又愛又恨的更新FIRMWARE的時間

今天的主角是他~~~~SUN 2540 醬

2540_front_zoom

這次要把FIRMWARE從六升到七,但因為網路上的文章少之又少,最後藉由大家的幫助下,找到一篇從七降到六的,去試看看能不能升上去。

要準備的東西

1.CONSOLE線

2.網路線&SWITCH

3.一台主機

本文開始,上課啦

CONSOLE使用9600 8 N 1,剛開始會看不到畫面,請CTRL+BREAK直到出現下面

Send <BREAK> for Service Interface or baud rate change

選到符合9600的RATE就OK了

會提示要輸入帳號密碼,是shellUsr/y2llojp,有時候只要密碼。

然後主機端要先把ftp server架設好,網路上都有相關的教學,那這邊就開始中間所輸入的指令

-> netCfgSet          //設定網路

Please wait…

‘.’ = clear field; ‘-‘ = to previous field; ^D = quit (keep changes)

==== STORED NETWORK CONFIGURATION ====
My Host Name :
IP Address if0 : 192.168.128.102          //硬碟櫃的IP
Subnet Mask if0 : 255.255.255.0          //遮罩
Server Host Name : tsuna          //ftp上的名稱
Server IP Address : 192.168.128.3          //ftp的IP
Gateway IP Address :
Network Init Flags : 0x00
User Name : tsuna tsuna          //ftp上新增的帳號
User Password : 1234          //帳號的密碼

Network Configuration successfully written to NVSRAM.

-> cd “tsuna:/”          //到FTP的根目錄下
value = 8 = 0x8
-> ls          //SHOW當下目錄的檔案
FTPServer.chm
FTPServer.exe
ftptrace.txt
license.txt
SUN2540_N1932-735843-902.dlp     //硬碟櫃的的NVSRAM FIRMWARE
SUN2540_RC_07355010_exmoor_apollo_1932.dlp //硬碟櫃FIRMWARE
users.xml
whatsnew.txt
如何移除.txt
阿榮福利味 – 免費軟體下載.url
-> fileDownload “SUN2540_N1932-735843-902.dlp”
value = 0 = 0x0
->
Opening file ‘SUN2540_N1932-735843-902.dlp’…
Reading file…
DOWNLOAD TO FLASH
Type Name Version Download Status
==== ============ ============ ===============
Cfg MfgConfig 07.35.00.00 Complete: 100% — Ok

Download stream processing complete (no errors)
fileDownload “SUN2540_RC_07355010_exmoor_apollo_1932.dlp”
value = 0 = 0x0
->
Opening file ‘SUN2540_RC_07355010_exmoor_apollo_1932.dlp’…
Reading file…
DOWNLOAD TO FLASH
Type Name Version Download Status
==== ============ ============ ===============
File PkgInfo 07.35.50.10 Complete: 100% — Ok
Boot Boot 07.35.50.10 Installed Ok
File System 07.35.50.10 Complete: 100% — Ok
File Diagnostics 07.35.50.10 Complete: 100% — Ok
File RAID 07.35.50.10 Complete: 100% — Ok
File DEBUG 07.35.50.10 Complete: 100% — Ok
File MAPI 07.35.50.10 Complete: 100% — Ok
File TAPI 07.35.50.10 Complete: 100% — Ok
File FBDT 07.35.50.10 Complete: 100% — Ok
File SPY 07.35.50.10 Complete: 100% — Ok
File LSI1068B0 07.35.50.10 Complete: 100% — Ok
File VSC7153_02 07.35.50.10 Complete: 100% — Ok

Download stream processing complete (no errors)

-> sysWipe          //類似清除舊資料的指令
sysWipe performed in a background task.
value = 67613784 = 0x407b458
->
04/01/16-06:17:21 (GMT) (sysWipe): WARN: The subsystem configuration has been destroyed – a full SUBSYSTEM reset is now MANDATORY
04/01/16-06:17:21 (GMT) (sysWipe): NOTE: If the system has dual controllers, sysWipe should be performed on each controller

->

到這邊之後,就可以帥氣的把硬碟櫃重開機

然後用CAM登入檢查FIRMWARE

SUN 2540 07.35.50.10 -2 SUN 2540 07.35.50.10

將將~~~~大功告成。

下課摟,大家要記得複習

Previous SUN server更新ALOM分位,use SUN Fire T2000
Next SUN TEST HDD
Table of Contents